Save
Busy. Please wait.
Log in with Clever
or

show password
Forgot Password?

Don't have an account?  Sign up 
Sign up using Clever
or

Username is available taken
show password


Make sure to remember your password. If you forget it there is no way for StudyStack to send you a reset link. You would need to create a new account.
Your email address is only used to allow you to reset your password. See our Privacy Policy and Terms of Service.


Already a StudyStack user? Log In

Reset Password
Enter the associated with your account, and we'll email you a link to reset your password.
focusNode
Didn't know it?
click below
 
Knew it?
click below
Don't Know
Remaining cards (0)
Know
0:00
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how

VCP Vsphere 4 misc

VCP Vsphere 4.0 Update 1 - Misc

QuestionAnswer
.vmdk Virtual disk file - describes virtual disk characteristics.
-flat.vmdk preallocated virtual disk file that contains the data
.vswp Swap file
nvram Non-volatile RAM file (vm BIOS)
.vmem VM memory
.vmss VM suspend file
<vm_name>.vmsd VM snapshot description file - empty if no snapshots.
-Snapshot.vmsn Snapshot state file
vmware.log VM log file
vmware-#.log old VM log entries, 6 maintained at a time, oldest deleted.
<vm_name>_#.vmdk, <vm_name>_#-flat.vmdk additional disk files.
Two files needed to recover a virtual machine <vm_name>.vmdk, <vm_name>-flat.vmdk, and additional volumes.
VMotion - datastore compatibility requirements Source and destination host must use shared storage (SAN or iSCSI). Shared storage may use VMFS or shared NAS.
VMotion - network compatibility requirements Requires a Gigabit Ethernet network. VMs on source and destination hosts must have access to same subnets.
VMotion - CPU compatibility Source and destination must have compatible sets of CPUs. VMotion will not work between Intel and AMD CPUs.
What are the key features of HA - automatic detection of server failures, initializes restart- automatic detection of OS failures (monitors heartbeat information), initializes restart- smart failover of vms to servers with best available resources (with DRS)- resource checks before r
What are the features of FT - seamless stateful failover - automatic creation of secondary virtual machines (happens after failover) - works with all types of shared storage - works with all OS's (with single virtual processor) - works with existing DRS and HA clusters
List all of the standard roles in Vsphere Server   no accessread-onlyadministratorvirtual machine power uservirtual machine userresource pool administratorvmware consolidated backup userdatastore consumernetwork consumervirtual machine administrator
describe scenarios for applying permissions   1-propogate down or apply only to immediate object2-user is a member of multiple groups with permissiosn on same object - apply all3-user member of multiple groups, permissions on different objects:  same permissions apply as if granted to user directly4
what tools can be used to optimize cpu cycles?   vmkernel - hyperthreading, load balancingvm owner - virtual smpadmin - limit, reservation, share allocation
what tools can be used to optimize RAM?   vmkernel - transparent page sharing, vmmemctl, vmkernel swap filesvm owner - available memoryadmin - limit, reservation, share allocation
what tools can be used to optimize disk bandwidth?   vm owner - vm file locationadmin - multipathing
what tools can be used to optimize network bandwidth?   vm owner - virtual switch with teamed nicsadmin - traffic shaping
What are management capabilities of a DRS cluster?   - initial placement- load balancing- power management- virtual machine affinity rules
What are requirements for DRS load balancing?   - hosts must be part of vmotion network- all hosts use shared vmfs volumes- vdisks accessible by source and destination hosts- volume sufficient size to store all virtual disks(DRS can still make initial placement recommendations without vmotion)
What are the 3 types of admission control?   - Host- Resource Pool- HA (configuration is compatible with needs)
Admission control restraints could disallow what?   - power on a vm- migrating to another host, cluster, or resource pool- increasing cpu or memory reservations of a vm
What are legitimate reasons to temporarily disable admission control?   - Purposefully violate constraints to place hosts in standby mode to test DPM- automated process would violate constraints, such as an upgrade from Update Manager- other testing or maintenance
What are the effects of moving a VM to a new resource pool?   - vm reservation and limit do not change- if vm shares are standard (high/medium/low), shares % adjusts to reflect shares in the new pool- custom shares are maintained (warning displayed if very large)
character limit for vcenter server names   15
what is hostd?   ESX host agent
What are hostd's functions?   - reports to and executes actions from management interfaces and vcenter server agent- authenticates task requests- includes an SNMP agent- uses TCP port 443- restarted from CLI with service mgmt-vmware restart
What is vpxd.exe?   Vcenter Server program that runs as Windows service
What is vpxa?   Vcenter server agent running on host machines
What are the functions of vpxa?   - communicates to vcenter server and relays tasks to hostd- uses tcp port 443- restarted from CLI by service vmware-vpxa restart
What are functions of vpxd.exe   - directs actions on hosts- monitoring and management- runs automatically in background, uses database
Name other Windows services that run on vcenter server and their function   * Mount Service - invoked during vm customization* Collector Provider - guided consolidation functionality* Collector Service - guided consolidation* Converter - machine import, export, conversion* orchestrator - orchestrator development interface* Manag
What is vpxuser?   Vcenter server entity with root privileges on hostscreated when host added to vcenter
What is a vlance adapter?   emulated AMD 10mbps NIC, highly compatible
VMXNET adapter   no physical counterpart, optimized for a VM, requires VMware tools
Flexible adapter   identifies itself as a vlance adapter to allow communication, and with vmware tools installed changes it to vmxnet
E1000 adapter   emulated Intel Gigabit Ethernet NIC, works in most newer versions of operating systems
VMXNET 2 (Enhanced) NIC adapter   Based on VMXNET but provides some high-performance features like jumbo frames and hardware offloads.  Only available to hosts 3.5 or later and to limited operating systems.
VMXNET 3 NIC adapter   Next gen paravirtualized NIC designed for performance, not related to earlier versions.  Adds multiqueue support, IPv6 offloads, only available to limited set of OS's.
What are default installed plug-ins?   vCenter storage monitoring, vcenter hardware status, vcenter server status
Maximum number of days for eval license?   60
Name the map views available in Vsphere client   - virtual machine resources- host resources- datastore resources- vmotion resources
What .net framework is required for the Vsphere client?   3.0 SP1
list IP ports used by VCenter   80 - direct ittp connections, redirected to 443389 - LDAP connections for directory services443 - default port vcenter listens for vcenter client connections636 - ssl port for vcenter linked mode902 - default vcenter port to send data to managed hosts.  
What is the purpose of host update utility?   For remote upgrades of standalone hosts.  Upgrades the service console (if present) and vmkernel.  Does not upgrade vmfsdatastores or or vm OS's
List the components that can be upgraded with VMWare Update manager   - Upgrade, updating, and patching clustered hosts, vms, and guest operating systems.  Recommended instead of host update utility on sites that have Vcenter Server.
List the hardware requirements for ESX 4   - 64-bit x86 processors (all AMD Opteron, numerous Intel)- 2GB RAM- STORAGE:  SCSI Adapter, Fibre Channel Adapter, or Internal RAID controller (software iSCSI not supported)
To upgrade to ESX 4, the /boot partition must have a minimum of how much disk space available?   100mb
What are advantages of a distributed versus standard vswitch?   - simplify datacenter administration- provide support for private VLANs- enable network stats and policies to migrate with vms during a vmotion migration [such as Rx rate limiting]- provide for customization and third-party devel [vnetwork switch APIs]
"Optional partition that changes ""/"" partition size" /usr
Where is the service console located In a VMDK on a local VMFS store or non-shared datastore
Upgraded by vCenter Update Manager " Service Console, Virtual machine Hardware, VMware Tools, VMFS Datastores"
updated by vCender Update Manager " Templates, ESX/ESXi Hosts, Virtual Appliances"
ESX Server Home Page Tasks " Download vCenter, Browse Objects Managed by this Host, Browse Datastores in this Host's Inventory"
ESX Post-Install Actions " Configure Licensing, Verify VMs, Connect to vCenter (if applicable)"
ESX Service Console FS structure " separate mount points for /var/log and swap by default, s.b. /tmp, /var/log and /home running out of space on / can cause vSphere client connectivity disruptions"
vSphere 4 Host Update Utility " peform a host compatibility check, upgraded standalone ESX/ESXi hosts, upgrades VMkernel, service console"
Max cores for Standard licensing 6
Port Groups and VLANS " 1 VLAN per port group, Multiple port groups per VLAN"
Traffic Shaping in vSphere Outbound Only - vSwitch or Standard switch port group; Inbound/Outbound - vDS dvPort or entire dvPort group
Notify Switches Option Physical switch is notifed when location of virtual NIC changes
Reasons to Boot from SAN " diskless hardware, easy replication of service console to remote site"
Items in Network Adapters section " Wake on Lan support, Speed and Duplex settings, Observed IP ranges"
LUN masking config for Boot from SAN " Boot LUN - Masked to only 1 Host, Datastore LUNS - masked to all Hosts"
vSphere virtual switch uplinks " uplink - Physical NIC, uplink is not required, vSwitch cannot share same uplink"
Enable NetQueue on Physical NIC and Advance Settings of Vmkernel
Load balancing policies for vDS " source MAC hash, explicit failover order, originating virtual port ID"
N-Port ID Virtualization requirements " not available for Storage Vmotion, Vmotion requires all mapping files on same datastore"
Beacon Probing identify when an upstream link failure has occurred
Gateway purpose in regards to Service Console Port " used for the default route, is required with 2 or more uplinks on same subnet"
Traffic Shaping is only available with VDS TRUE
Lun masking for non-ESX servers should be on SAN storage device TRUE
Forged Transmits Allows a VM to transmit packets that contain a MAC address othe than the address defined for the VM
Powered On VMs in vCenter Max (32/64) " 2000, 3000"
Registered VMs in vCenter Max (32/64) 3000/4500
Pluggable Storage Architecture (PSA) " Associates physical paths w/ logical devices, I/O queing to logical devices, I/O queueing to physical storage HBAs"
Adding Service Console networking to VDS " Service Console network Adapter can be created and added to Standalone Port, or associated with an existing port group on a Network Distributed Switch, Migrated from an existing standard vSwitch"
Apps requiring RDM LUN to used Physical Compatibility Mode " SAN Management Agents, P2V Clustering, SCSI-target based software"
Primary VLAN in a Private VLAN is considered Isolated TRUE
Migrating VM from Standard to Distributed switch " Edit Network Adapter settings of VM and select dvPort group, Select the VM using the Migrate Virtual Machine Networking option"
Functions of zoning in FC Switches " Prevent non-ESX hosts from accessing VMFS data, Restrict connection on a storage array to ESX Hosts that utilize the array"
Which vSphere features support RDM using PCM? " Vmotion, HA"
Write Process by Vmkernel to FC Storage Array " File corresonding to the VM is located on the VMFS datastore, modified I/O request is sent to physical HBA, block requests on virtual disk are mapped to physical disk"
Benefits of Virtual Compatibility mode for RDMs " Allow templated creation, Allow Cloning"
Hardware iSCSI initiators offload the following from the Vmkernel " Encapsulation of I/O requests into iSCSI Protocol Data Units (PDUs), Encapsulation of iSCSI PDUs into TCP/IP packets"
Enable Jumbo Frames for software iSCSI intiator " Vmkernel port, virtual switch"
Runtime Name for FC storage Device The name of the first discovered path to the device in vmhba:C:T:L format
Connecting the iSCSI software initiator to the VMKernel Ports requies the use of this: esxcli
Predictive Scheme for VMFS Utilizes several LUNs with different storage characteristics
Adaptive Scheme for VMFS utilizes a small number of Large LUNs
vSphere features that can use NAS/NFS " HA, Snapshots, Storage Vmotion, VMware Consolidated Backup"
To grow VMFS store on ESX? Use the MVFS Volume Grow from ESX Host
vCenter Maps displays what resources? " Datastore, Host, Cluster, MV SCSI Volume, NAS Mount, SCSI Adapter, SCSI Target, Datacenter"
vCenter Reports displays what resources? " Space Used, Snapshot Space, Multipathing status for VM, Number of Virtual Disks"
Actions via Plug-In Manager? " Enable an installed Plug-in, View available plug-ins not installed,Disable Plug-in"
Sizing vCenter Database per statistics level number of entities (hosts+VMs) x Statitic per entity variable
Statistics per entity variables (1/2/3/4) 10/25/65/100
Space needed per 50/100 VMs at default stat levels ~700MB/1GB
Services available only through vCenter " HA, DRS, Data Recovery"
What pre-defined vCenter Server Role can assign permissions to users? Administrator
vApp " a logical entity comprising one or more virtual machines, which uses the industry standard Open Virtualization Format to specify and encapsulate all components of a multi-tier application as well as the operational policies and service levels associated w
vAPP Creation conditions " A folder is chosen in the VM and Templates view, a DRS-enabled cluster is chosen, Host is running > ESX 3.0"
Update Manager Serverity Levels " Low, Host General, Critical, General, Security"
Max Characters in a vApp name 80
vApp IP Allocation Policy options " DHCP, Fixed, Transient"
Virtualized Memory Management Unit (MMU) Enables memory reclamation from the guest OS and is required for VM Direct Patch PCI devices
vApp Objects " Resource Pools, vApps, VMs"
Creating a host profile " Create from an existing ESX 4 host, Import a profile from an existing .vpf file"
Host Profile editor sub-profile configurations " Advanced, Security, Memory Reservation"
Default upgrade baselines in UM " VMware Tools upgrade to Match Host, VA Upgrade to Latests"
Created by: mbender
Popular Computers sets

 

 



Voices

Use these flashcards to help memorize information. Look at the large card and try to recall what is on the other side. Then click the card to flip it. If you knew the answer, click the green Know box. Otherwise, click the red Don't know box.

When you've placed seven or more cards in the Don't know box, click "retry" to try those cards again.

If you've accidentally put the card in the wrong box, just click on the card to take it out of the box.

You can also use your keyboard to move the cards as follows:

If you are logged in to your account, this website will remember which cards you know and don't know so that they are in the same box the next time you log in.

When you need a break, try one of the other activities listed below the flashcards like Matching, Snowman, or Hungry Bug. Although it may feel like you're playing a game, your brain is still making more connections with the information to help you out.

To see how well you know the information, try the Quiz or Test activity.

Pass complete!
"Know" box contains:
Time elapsed:
Retries:
restart all cards