Popular Respiratory Therapy sets

 

 


shouldUsed in 3 bottle system. 1.Suction Control 2.Water Seal 3.Collection bottle. When Collection chamber is full replace whole unit. 1-2cm H2O should be placed in Water seal bottle. 15-20cm H2O _____ be placed in suction control bottle11true
bottleFrom pt. a tube E enters a collection _____. Fluid drops to bottom &gas is pulled in other tube. TubeD enters water seal bottle gases are drawn thru a tube. i.e Submerged under H2O(Gentle bubbling is seen). TubeC enters suction control bottle no bubbling21true
systemsWhat are the types of chest drainage _____?30true
uniformlyNon particle-size water that is distriuted _____ in the air.41true
sourceIt can be a _____ of contamination.51true
drainageWhat are the potential problemscollection bottle is developing fluid quickly @ >100 ml/hr found during monitioring a chest _____ system?60true
system1. Temperature is increased. 2. Surface area of the water is increased. 3. Pressure in the _____ is decreased.71true
Aerosol1. Humidity and _____ therapy and 2. Chest tubes and drainage systems.81true
existsWhat conditions must _____ when removing/discontinuing a chest tube?90true
potentialWhat are the _____ problems when there is no bubbling in the suction control bottle found during monitioring a chest drainage system?110true
aerosolWhat happens when there is a particle deposition in an _____ therpay?120true
surgicallow return volume in a mech. Vent - It means lost volume thru the lung & the Chest Tube. 1. Adjust VT to maintain desired ABG values. 2.Hole in the Lung may need _____ repair.131true
unclamping1. Indicates a leak b/w pt.&water-seal bottle. 2. If all connections are secure-begin _____ tube E where the tube exists the pt. If bubbling stops then leak is inside the pt.& surgery is needed.141true
Sterile1. Pull the Tube during a Valsalva Manuever after complete exhalation 2. The side should be covered with petroleum based Jelly &_____ gauze. 3. Pulse X-ray should be taken151true
airwaysAerosols are not natural to the _____ and may cause irritation, bronchospasm.161true
achieveIt is the amount of water (humidity) the body needs to makeup from ambient air in order to _____ 100%. It is expressed as mmgH20/L of gas. The body needs 44 mg H20/L of gas.181true
controlSuction is not enough -not enough water in the suction _____ bottle.191true
breath1.If no output - check medications, fluid level, device for proper function - Commonly need to increase the flow 2. If aerosol doesn't disappear during an inhalation, instruct pt. to _____ thru mouth - Not thru Nose201true
tube(CTPneumothorax -Air &Hemothorax -Fluid &Air in pleural space causing lung collapse.If > 20% of lung need a chest _____) based on X-ray &BS.Pleural Effusion -Excess Fluid causes Lung Spaceloss treat by inserting needle in space to relievepressure;insert CT211true
Vaccum1. Ensure there is suction coming from the wall. 2. Ensure bottle system is below insertion site of chest tube. *sometimes systems use gravity alone. There is no vaccum. These systems work fine. _____ only assist evacuation.221true