Image Acquisition

        Help!  

Question
Answer
The component of a CR image plate that records the radiologic image is   photostimulable phospor  
🗑
the luminescent light emitted by the PSP is transformed into the image seen on the CRT by the   ADC (analog to digital converter)  
🗑
SId affects recorded detail in which of the following ways?   directly related  
🗑
Grid interspace material is made up of what?   Aluminum and plastic fiber  
🗑
In a duration of 0.05 second was selected for an exposure what mA would be necessary to produce 30 mAs?   600 mA  
🗑
Unopened boxes of radiographic film should be stored away from radiation and   in the vertical position  
🗑
The term windowing describes the practice of   changing the image brightness and/or contrast scale  
🗑
foreshortening can be caused by   the radiographic object being placed at an angle to the IR  
🗑
what does not affect the exposure rate of the primary beam?   field size  
🗑
a patient with Congestive heart failure has to have what done to the technique for a PA chest Xray?   Increase  
🗑
Misalignment of the tube-part-IR relationship results in   shape distortion  
🗑
the direction of electron travel in the xray tube is   cathode to anode  
🗑
for the same FOV the spatial resolution will be improved using   a larger matrix  
🗑
which of the following technical change would best serve to remedy the effect of very dissimilar tissue densities   high KV exposure factors  
🗑
the absorption of useful radiation by a grid is called   grid cutoff  
🗑
during CR imaging, the latent image present on the PSP is changed to a computerized image by the   ADC  
🗑
How are mAs and patient dose related?   directly  
🗑
the reduction in xray photon intensity as the photon passes through material is termed   attenuation  
🗑
diagnostic xrays are generally associated with   high frequency and short wavelength  
🗑
At what portion of the xray beam is the effective focal spot the largest?   at the cathode end  
🗑
the intensity of ionizing radiation decreases as   distance from the source of radiation increases  
🗑
what is the purpose of the thin layer of lead that is often location in the rear portion of the IP   to prevent scatter radiation  
🗑
the purpose of the electroconductive layer of the CR PSP plate is to   facilitate transportation through the scanner/reader  
🗑
the xray image seen on the computer display monitor is a   digital image  
🗑
the accessory used to measure the thickness of body parts in order to determine optimal selection of exposure factors is the   caliper  
🗑
a radiograph made with a parallel grid demonstrates decreased density on its lateral edges. this is most likely due to   decreased SID  
🗑
a particular mAs value, regardless of the combination of the mA and time, will reproduce the same radiographic density, this is a statement of the   reciprocity law  
🗑
the relationship between the height of a grid's lead strips and the distance between them is referred to as grid   ratio  
🗑
because of the anode heel effect the intensity of the xray beam is greatest along the   cathode end of the beam  
🗑
in digital imaging, TFT DEL size is related to   spatial resolution  
🗑


   

Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
 
To hide a column, click on the column name.
 
To hide the entire table, click on the "Hide All" button.
 
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
 
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.

 
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: jfwoodard
Popular Radiology sets