wwall RT 2 Test 1
Help!
|
|
||||
---|---|---|---|---|---|
What is a SPAG | show 🗑
|
||||
show | SPAG
🗑
|
||||
show | ultrasonic nebulizer
🗑
|
||||
show | fine
🗑
|
||||
show | radio frequency generator produces high frequency vibrations across piezoelectric transducer or crystal, breaks up meds, frequency determines particles size, amplitude determines volume
🗑
|
||||
Best nebulizer of choice for pt with thick retained secretions | show 🗑
|
||||
How does RTT control the volume on a USN | show 🗑
|
||||
Hazards of USN | show 🗑
|
||||
Why must RTT be concerned about condensation in the tubing during neb treatment | show 🗑
|
||||
show | tent or hood
🗑
|
||||
show | condensation in the tube increases FIO2
🗑
|
||||
show | non heated low humidity appox 25 percent body humidity
🗑
|
||||
What is a bubble humidifier | show 🗑
|
||||
show | high output aerosol neb often used with CPAP, heated, uses evaporation to produce high humidity at high flow (misty ox)
🗑
|
||||
What is the cascade humidifier | show 🗑
|
||||
What is a wick or concha humidifier | show 🗑
|
||||
show | heat moisture exchange, device placed between pt and wye on vent circuit, body humidity is collected and then used to humidify next insp, ideally 70-90 humidity is produced
🗑
|
||||
How often do we change out the humidifier circuit to prevent pseudomonas | show 🗑
|
||||
Therapeutic range for aerosol meds is | show 🗑
|
||||
What is an HHN | show 🗑
|
||||
What is the volume of an SVN | show 🗑
|
||||
show | 1.5 to 7 microns
🗑
|
||||
show | tamadine or pentamidine medication for treating C Pneumonia in AIDS pts
🗑
|
||||
show | breath actuated nebulizer used in many hospitals today, saves meds and gives shorter treatment
🗑
|
||||
show | spacer and good pt education
🗑
|
||||
DPI is what | show 🗑
|
||||
What is the downside of DPI | show 🗑
|
||||
What is the upside to DPI’s | show 🗑
|
||||
What is the purpose of large volume nebs | show 🗑
|
||||
Allegiance health LVN | show 🗑
|
||||
show | air entrainment 60-90 percent on flows of 42 to 77 L/M
🗑
|
||||
Misty ox gas injection neb or GIN | show 🗑
|
||||
show | used if giving continuous aerosolized meds like albuterol for status asthmaticus, 240 ml reservoir
🗑
|
||||
show | water in a gaseous states
🗑
|
||||
show | convenient, inexpensive, portable, no drug prep, hard to contaminate
🗑
|
||||
What are the disadvantages of MDI | show 🗑
|
||||
show | less pt coordination, high doses, even and continuous, no CFC
🗑
|
||||
What are the disadvantages of svn’s | show 🗑
|
||||
show | wheezing and bronchospasm esp with copd, broncoconstriction with artificial airway, infection, overhydration, pt discomfort, rtt exposure, edema
🗑
|
||||
Contraindications of aerosol are | show 🗑
|
||||
show | upper airway edema (cool), LTB, subglottic edema, post extubation edema, post op mgmt of upper airway, sputum specimen or mobilize secretions
🗑
|
||||
show | 44 mg/L always, regardless of body temp or outside temp
🗑
|
||||
Actual humidity | show 🗑
|
||||
show | liquid particles suspended in gas
🗑
|
||||
show | sterile hypo, hyper or normal saline in aerosol
🗑
|
||||
What is the primary purpose of humidity therapy | show 🗑
|
||||
What is the secondary purpose of humidity therapy | show 🗑
|
||||
How do you tell if a non heated humidifier has a leak | show 🗑
|
||||
Where do you monitor temp of humidity | show 🗑
|
||||
show | wick-air flows over wick, membrane-gas passes through hydrophobic membrane, USN-prezo electronic crystal
🗑
|
||||
Contraindications of HME | show 🗑
|
||||
show | under hydration, mucus plugging, increased WOB, hypoventilation from increased dead space, ineffective pop off, hypothermia
🗑
|
||||
Contraindications for heated humidifiers | show 🗑
|
||||
Hazards of heated humidifiers | show 🗑
|
||||
Relative humidity is | show 🗑
|
||||
show | all vent patients with endotrach or tracheostomy, primary – pt receiving dry gas, upper airway bypassed, secondary – mgmt of hypothermia and bronchospasm from cold air
🗑
|
||||
Which nebulizer administers particles with sizes 0.5-3.0 microns and allows for the greatest deposition of aerosol? | show 🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
williamwallace
Popular Respiratory Therapy sets