Rad Protection Procs Test

Enter the letter for the matching Answer
incorrect
1.
The PBL must be accurate to within ___% of the SID
incorrect
2.
All diagnostic x-ray beams must have a total filtration of at least ____ when operated above 70 kVp
incorrect
3.
1/16 of lead is equivalent to ___ inches of masonry.
incorrect
4.
What is the dose limit for occupational exposure (effective dose)
incorrect
5.
Nonoccupationally exposed
incorrect
6.
The percentage of time during which the x-ray beam is on and directed toward a particular wall is called _____ ______.
incorrect
7.
The instrument of choice for measuring radiation intensity in areas around a fluoroscope is called the _________ ________.
incorrect
8.
Define major organogenesis.
incorrect
9.
The bucky slot cover for fluoroscopic units should be at least ___ equivalent.
incorrect
10.
An __________ ______ can be occupied by anyone.
incorrect
11.
The image intensifier assembly serves as a primary protective barrier and must be ___ equivalent.
incorrect
12.
_______________ is the emission of light by a thermally stimulated crystal following irradiation.
incorrect
13.
TLDs can be worn for intervals up to _______
incorrect
14.
General population dose limit (INFREQUENT) is:
incorrect
15.
Radiographic tubes operated between 50 and 70 kVp must have at least ___ of filtration.
incorrect
16.
Radiographic tubes operated below 50 kVp must at a minimum of ___ total filtration.
incorrect
17.
General population dose limit (FREQUENT) is:
incorrect
18.
The variation in x-ray exposure should not exceed ___%
incorrect
19.
Which cells are most radiosensitive?
incorrect
20.
Leakage radiation must be less than ___ at a distance of __ from the protective housing.
A.
Uncontrolled area
B.
2.5mm Al
C.
One year
D.
0.5mm Al
E.
1.5mm Al
F.
0.25mm Pb
G.
100 mR/hr, 1 meter
H.
2
I.
1/10 for that of radiation workers
J.
5
K.
Lymphocytes, spermatogonia, erythroblasts
L.
2mm Pb
M.
ion chamber
N.
TLD (thermoluminescence dosimetry)
O.
4
P.
50 mSv/yr
Q.
5 mSv/yr
R.
1 MsV/yr
S.
use factor
T.
2nd week to 10th week of pregnancy.
Type the Answer that corresponds to the displayed Question.
incorrect
21.
True or false: The TLD can only be used once.
incorrect
22.
Education and training exposure:
incorrect
23.
Entrance skin exposure is most often referred to as ____________ ___________.
incorrect
24.
An area occupied primarily by radiology personnel and patients is called a _________ ____.
incorrect
25.
The level of radiation activity in a room is known as _______.
incorrect
26.
Dose limit for pregnant technologist:
incorrect
27.
_________ speed rather than _________ speed controls patient dose.
incorrect
28.
The total filtration of the fluoroscopic x-ray beam must be at least ___ equivalent.
incorrect
29.
The protective curtain or panel of a fluoroscopic unit must be at least ___ equivalent.
incorrect
30.