Medical Gases Test

Enter the letter for the matching
incorrect
1.
What type of safety system is used for E tanks or smaller? (IE)
incorrect
2.
3AL in the specifications on a cylinder would indicate what? (IE)
incorrect
3.
When a large tank is over filled and the tanks safety relief is activated which of the following has occurred? A. Frangible disk has exploded B. Gas is vented to the atmosphere C. Temp. inside the tank has risen too high D. A,B and C (TJ
incorrect
4.
When using a bourdon gauge and a occlusion occurs distal to the gauge, the bourdon gage will: A. Read the correctly no matter what B. Reads higher than actual L/min C. Reads higher than actual L/min D. Reads lower than actual L/min (TJI)
incorrect
5.
A regulator is what two things combined?(IE)
incorrect
6.
Which of the following is NOT a characteristic of Oxygen? A. Colorless, odorless, tasteless B. Non-flammable C. Supports combustion D. Will combine with all elements and inert gases. (TJI)
incorrect
7.
A patient has a "E" cylinder at home for oxygen. A cylinder of Air was delivered by mistake. What would insure that the patient would not receive the contents of the air cylinder A. PISS for O2 is 2-5 B. PISS for O2 is 1-5 C. Both A and C (TJ
incorrect
8.
5. A H cylinder reading 1500 psi with the flow set at 5 l/min will need to be changed out when? (IE)
incorrect
9.
You have a tank with the stampings DOT.3AA.2015 on the side. What does the (2015 represent? A. Service pressure B. Maximum fill pressure C. Both A and B (TJI)
incorrect
10.
3. If you put a flowmeter into a gas outlet and the ball in the Thorpe tube jumps this would indicate what? (IE)
A.
D. A, B and C
B.
reducing valve and flowmeter
C.
D. Will combine with all elements and inert gases.
D.
The Thorpe tube is compensated
E.
It is made of aluminum
F.
B. Reads higher than actual L/min
G.
A. Piss for O2 is 2-5
H.
C. Both A and B
I.
about 15 hours and 30 mins
J.
Pin-Index safety system( PISS)
Type the that corresponds to the displayed Question.
incorrect
11.
2. If you look at a Thorpe tube and the needle valve is positioned upstream or proximal to the actually tube this would indicated what?(IE)
incorrect
12.
What safety standard is founf on larger tanks, such as G and H cylinders? A. PISS B. DISS C. ASSS D. Quick connect systems (TJI)
incorrect
13.
What is the cylinder color code for Helium A. Brown B. Gray C. Orange D. Black (TJI)
incorrect
14.
A hydrostatic date testing date of "12 10" on a cylinder means the next testing date will be due on which following date? A. 01/16 B. Dec. 2015 C. 11/15 D. Dec. 2020 (TJI)
incorrect
15.
How long will a E cylinder of oxygen with 2200 psi of pressure and a flow rate of 4 L/min last A. 90 min. B. 153 min. C. 2 hrs. D. 1 1/2 hrs. (TJI)
incorrect
16.
It is ok to use a cylinder of oxygen that does not contain a label as long as it is green in color. A. True B. False (TJI)
incorrect
17.
A patient is to be taken to have an MRI it will take approx. 30 min. The patient needs at least 10 L/min of oxygen. Which of the following E cylinders has the lowest amount of oxygen that you can safely use? A. 2200 psi B. 900 psi C. 1100 psi (T
incorrect
18.
Which type of safety system will prevent you from connecting an air flowmeter to an oxygen station outlet? A. PISS B. DISS C. ASSS (TJI)
incorrect
19.
4. If you had to transport a patient and knew the only way to continue the patient’s O2 therapy was to lay the cylinder down flat what king of flowmeter would be most appropriate? (IE)

Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.

  Normal Size     Small Size show me how
Created by: conniec0005
Popular Respiratory Therapy sets