Mammography2 Test

Enter the letter for the matching Answer
incorrect
1.
The screen-cleaning test should be carried out whenever
incorrect
2.
In mammography, selecting extremely low kVp values
incorrect
3.
For the repeat analysis to be meaningful, a patient volume of at least ___ patients is needed.
incorrect
4.
The criteria to pass the ACR Mammography Accreditation on conventional phantom imaging require a minimum of ___ masses.
incorrect
5.
The characteristic curve, obtained by plotting density values from a sensitometer, can be used to assess all of the following exvept:
incorrect
6.
Adequate "air bleed time" refers to the
incorrect
7.
An MQSA certificate is issued when a mammography facility has been accredited. This certification is valued for
incorrect
8.
Mammography facilities can receive certification from
incorrect
9.
Which of the following characteristics are unique to mammography cassettes?
incorrect
10.
AEC failure, resulting in an underexposed radiograph, can be caused by
incorrect
11.
One of the two reasons towels are used in the compression test is to
incorrect
12.
In establishing processing quality control operating levels, the speed index is designated as the density
incorrect
13.
Before processing the sensitometric strip each day, the mammographer should
incorrect
14.
Proving that a darkroom fog failure is a result of safelight problems involves
incorrect
15.
In the darkroom fog test, the optical density difference between fogged and unfogged areas of the film should not exceed
incorrect
16.
For the daily quality control testing, the base-plus-fog level should remain within
incorrect
17.
Daily processor control is used to
incorrect
18.
If any of the visual checks fail, the first step is to
incorrect
19.
Which of the following affects focal spot size?
incorrect
20.
The primary goal of compression is to
A.
-the FDA -an SAC state
B.
0.05
C.
angle of the anode
D.
three
E.
increases contrast but increases patient dose
F.
to compare the x-ray beam quality with different films
G.
repeating the test with the safelights off
H.
+0.03 of the established levels
I.
generally have a single intensifying screen.
J.
3 years
K.
a mammographer notices dust artifacts on the image
L.
protect the cassette holder
M.
-determine the film speed -check the film contrast -check the stability of the processor
N.
correct or replace the item
O.
improper placement of the dense breast tissue/size over the detector
P.
allow uniform penetration of structures within the breast.
Q.
elapsed time between film loading and exposure
R.
closest to but not less than 1.20
S.
250
T.
check the developer temperature
Type the Answer that corresponds to the displayed Question.
incorrect
21.
In imaging the phantom, the technical factors used should be the same as those used clinically for a __-cm-thick breast of medium glandularity.
incorrect
22.
If the patient volume at a mammography site is 200 patients per week, the repeat/reject analysis should be done every
incorrect
23.
The phantom image background optical density should never be
incorrect
24.
Which of the following quality control tests does not require a densitometer?
incorrect
25.
Digital images can be viewed on a computer monitor or printed using
incorrect
26.
Which of the following mammographic quality control tests is performed monthly?
incorrect
27.
The darkroom fog test is performed
incorrect
28.
As the size of the x-ray field decreases, to maintain a constant image density the exposure will
incorrect
29.
In mammography, the commonly used focal spot size for routine work is
Type the Question that corresponds to the displayed Answer.
incorrect
30.
films that involve exposure to the patient