Exposure Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| When is scatter radiation produced? | when the xray beam attenuates matter |
| When is scatter not produced? | when the beam fully penetrates matter |
| What are the 3 types of scatter radiation produced when it is absorbed my matter? | Coherent Scattering, Compton Effect, Photoelectric effect |
| What is secondary radiation? | Radiation produced by the photoelectric effect. |
| What else besides the body can produce scatter? | tabletop, IR or any other matter in the radiation field. |
| What is another name for Coherent scattering? | Thompson scatter |
| When does Coherent scattering take place | at low energy levels |
| When does the Compton effect occur? | between 40 - 125 kVp |
| what is the compton effect? | when an x-ray photon interacts with an outer orbital electron |
| what is back scatter? | when x-rays or photons are traveling towards the tube instead of away from it |
| As the kVp is increased, Compton interactions are ...? | increased |
| What kind of radiation is the photoelectric effect similar to? | Characteristic radiation |
| With the photoelectric effect photons are interacting with what, instead of the tungsten? | The body |
| In a photo electric interaction what happens? | an x-ray photon interacts with an inner orbital electron |
| The majority of radiation interactions with the body are what type of effect? | Compton effect |
| As the kVp is increased, photoelectric interactions are ...? | decreased |
| What is Fog? | Unwanted exposure to an image |
| mA is/controls what? | overall blackness on your film/density |
| Scatter creates fog that reduces what? | Contrast and visibility of detail |
| these 4 things affect scatter and fog.. | volume of tissue, kVp, density of matter, field size |
| the denser the body part, the ..? the scatter. | the less the scatter |
| What is the main source of scatter? | The patient |
| what is the principal method for reducing scatter? | A grid |
| When is a grid used? | when the kVp is greater than 60 or the body part is 10-12 cm in thickness |
| Grids are usually held together by a radiolucent inter-spacing material which is? | aluminum |
| What is radiation that is passed through the body to the IR called? | remnant radiation |
| What is grid ratio? | the relationship between the height and width of the lead strips |
| what is a general purpose/chest xray grid ratio? | 12:1 |
| what is grid frequency and what is it's range? | the number of lead strips per square inch, 60-196 |
| a buckey is what? | a moving grid |
| Excessive absorption of useful radiation by the grid is what? | Grid cutoff |
| When does grid cutoff happen? | when the X-ray tube is off to one side instead of focused to the middle, or when the tube is angled to one side |
| Why are lower grid ratio grids used bedside or portable? | because it is more difficult to get alignment exactly right bedside |
| What is a coned-down image? | x-ray of a very small area of the subject. |
| What two ways does decreasing the kVp increase the contrast? | narrows the scale of contrast, decreased scatter and fog |
| What manual technical factors are considered when using an exposure chart? | SID, pt size, kVp, mA, exposure time, and grid notation. |
| True or false - Technique charts are unique to each x-ray machine and each facility. | True. |
| A change in ...? kVp below 85, a change of ...? kVp is sufficient. | below = 2 above=3 |
| What is quantum mottle? | noise, starvation of mA |
| what is the minimum change (in mAs) necessary to see change on a film? | 30% |
| according to the 15% rule- To decrease contrast you... | Increase kVp by 15% (10 kVp) and divide mAs by 2 |
| the primary consideration that affects volume of scatter is? | volume of tissue |
| Fixer solution does what? | removes unexposed silver bromide crystals from the emulsion of the film |
| four prime factors of radiology are what? | mA time kVp and distance |
| mAs is what to contrast? | a secondary factor of contrast |
| 1/2 mA, time or mAs = what? | half density |
| to double the density, what do you do to your kVp? | increase it by 15% |
| a muscular pt requires you to do what? | increase kVp |
| Define Inverse square law. | intensity of radiation at a given distance from the point source is inverse |
| When do you use the inverse square law? | when you see MR, I, R... whenever you are dealing with intensity |
| when do you use mAs distance formula? | when you are dealing with mAs, mA, or S |
| when do you use the rule of thumb? and what is it? | if the distance is either doubled or cut in 1/2 you multiply or divide by 4. closer * farther / |
| What 5 factors can affect density? | kVp, distance, processing, screen speed, anode heel effect |
| What is the law of reciprocity? | when you can change the mA and the S but still maintain the same mAs |
| what is the composition of film? (4 things) | base, adhesive, emulsion, super coat |
| a preservative in the developer does what? | helps decrease oxidation |
| Exposed silver bromide has what electrical charge? | negative |
| The restrainer in the developer does what? | limits developer to only exposed silver halide crystals |
| what is found in both the developer and the fixer to prevent oxidation? | preservative |
| what temp does the dryer dry the film? | 110 |
| what part of the intensifying screen emits light? | phosphor layer |
| why is rare earth more desirable? | is more efficient, 1200 times faster |
| why is the back of a cassette lined with lead? | to absorb back scatter |
| a sensitometry checks what? | the processor and varying scales of density |
| safe light should be? | 3-4 feet from the work bench |
| what is quantum mottle? | phenomenon that may dramatically affect recorded detail when high speed intensifying screens are used with low mAs. "starvation of mAs" |
| what do you get when quantum mottle occurs? | uneven density |
| when you increase the developer time, temp, and/or replenishment rate, what happens to the density? | it is increased |
| What is the practical application of the inverse square law formula? | mAs distance formula |
| small focal spot gives you what? | more detail and less heat capability |
| in manual processing, if the developer temp is up, what should happen to the developing time? | should be decreased |
| what controls the processing time? | roller transport system |
| you can increase kVp how? | majors by 10, minors by 2 |
| what is the temperature and humidity of the darkroom? | 60-70 degrees at 40-60% humidity |
| The amount of silver hilide crystals that are exposed determine what on your film? | amount of black |
| attenuation is what? | absorption with scatter |
| scale is refers to what? so a small scale would mean what? | contrast, small scale= high contrast |
| mA stations range from | 25-300 |
| the higher the scree speed the ..? mAs you need | less |
| generally when you use a grid you need ... times the mAs | 4 times |
| what occurs when phosphors absorb radiation and produce light? | florescence |
| who was credited with permanent photographic process? | Joseph Niepce |
| where do the photons come from? | effective focal spot |
| the sensitivity speak is made of what? | gold-silver sulfide |
| the size of the lattice gate determines what? | the amount of blackness on your film |
| yellow smudges are a result of what? | exhausted fixer |
| high contrast is considered to be more consistent in radiographic quality? t/f? | False |
| the grid ratio is determined by the height and amount of lead strips? T/F | False, it's measured by the height and the width |
| Contrast, Density, Distortion and Detail are examples of what? | Image quality factors |
| small focal spot is usually how many mm? Large focal spot? | .6mm and 1.2mm |
| what affects the size of penumbra? | focal spot |
| When OID decreases, penumbra... | decreases. better recorded detail |
| what is the digital phrase for recorded detail, density and what controls contrast? | Spatial resolution, brightness, window width |
| Shape distortion is controlled by what? | Unequal magnification |
| What geometric factors affect spacial resolution? | OID SID focal spot size |
| Air gap technique gives you as much clean up as what? And is done with a ... inch air gap | 15:1 grid, 10 |
| Films will show low contrast if the developer is set too ....? | Low |
| High contrast... 4 things about it | Few shades of gray, increased contrast, low kVp, short scale contrast |
| Low contrast... 4 things about it | Many shades of gray, decreased contrast, high kVp, long scale |
| What is the purpose of contrast? | to enhance detail on the film and differentiate structures |
| What are the 3 types of contrast? | Subject, Film, Radiographic |
| Bone absorbs more or less radiation? | more |
| the primary cause of fog is ? | secondary (scatter) radiation |
| When you increase the kVp by 10 you .... or else you are doubling your density | Cut the mass in 1/2 |
| what size are bucky grids? | 17x17 |
| What types of grids movements are there? | reciprocating and oscillating |
| how do you calculate grid ration and grid frequency? | ratio = h/D freq= 1/t+D (D= inter space distance, t = lead height) |
| If height remains the same, then a decrease in width will cause a decrease/decrease in grid ratio? | increase |
| Radius refers to the alignment of the focusing of the lead strips to the diverging primary beam t/f? | True |
| What is the HLV? | Half Layer Value, amount of absorbing material that will reduce the density by 1/2 |
| Compound filtration does what? | Absorbs the characteristic photon of the previous filter . |
| T/F what ever you collimate to will be the size of the divergent beam no matter the OID | True |
Created by:
christina325