B-General Building 7 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| Cal/OSHA requires any time a worker can fall __________ the worker needs to be protected | 7 1/2 feet |
| Top Rails and mid rails must be at least _________ in diameter to prevent cuts or lacerations | 1/4 inch |
| If wire rope is used for a top rail, it must be flagged every ______ | 6 feet |
| A top rail on a guard rail system must be installed at | 42 inches plus/minus 3 inches |
| Midrails, mesh, screens, vertical members must be installed on a guard rail system if there is no parapet wall at least __________ | 21 inches high |
| The guard rail system must be allowed to withstand a force of __________ | 200 pounds applied two inches on the top edge in any direction |
| Mid-rails in a guard rail system must be allowed to withstand a force of | 150 pounds |
| ___________ must be erected around all sides of roof work areas | Guard rails and Warning Lines |
| What is PFAS | Personal Fall Arrest System |
| A PFAS must limit the maximum arresting force on any employee to ________ | 1,800 pounds |
| A PFAS must not allow a worker to fall more than | 6 feet |
| A PFAS must bring a worker to a complete stop, and limit maximum deceleration distance to | 3.5 feet |
| A PFAS, safety belt, or lanyard must be able to support a minimum dead weight of | 5,000 pounds |
| If workers are working more than 25 feet above ground or water, a __________ is required | Safety Net |
| Nets must extend _________ beyond the edge of the work surface | 8 feet |
| A Net can be installed no more than _________ below the work surface | 30 feet |
| Scaffolds are required when work cannot be safely done on ______ | Ladders |
| What are the two exceptions to the Scaffold requirements | 1) less than 20 inches in width and 15 feet in heighth 2) 12 inch Planks on joists 2 feet O.C |
| Each Scaffold should be designed to hold its own weight plus ________ times the intended maximum working load | 4 |
| Each plank on a Scaffold that is 10 feet or less should not hang over the edge more than ____________ | 12 inches |
| Each plank on a Scaffold that is 10 feet or longer should not hang over the edge more than __________ | 18 inches |
| Planking on Scaffold must be at least | 2 inches thick and 10 inches wide |
| FPS must be installed on any scaffold more than ________ above a lower level | 10 feet |
| Full Guard rail system must be installed on Scaffolding at | 10 feet |
| a Manually Propelled Mobile Scaffold cannot exceed __________ | 4x the minimum base dimension |
| Insulated Power Lines cannot be closer than _______ to a Scaffold | 3 feet |
| Un-Insulated Power Lines cannot be closer than ________ to a Scaffold | 10 feet |
| All extension ladders should be placed at a _________ degree angle | 75 |
| Never stand on the top _________ rungs of a stepladder | 2 |
| Never stand on the top __________ rungs of an extension ladder | 3 |
| An extension ladder must extend at least _________ above the surface | 36 inches |
| The two sections of the extension ladder must overlap at least __________ | 36 inches |
| The base of the ladder should be ___________ lengths away from the base of the building | 1/4 of the roof height |
| All receptacle outlets that are not part of the buildings permanent wiring must be _______ | GFCI protected |
| What does PPE stand for | Personal Protection Equipment |
| Who must provide the PPE for the employees? | The employer must, at NO cost |
| When does CAL/Osha require hearing PPE | If the 8 hour average sound level is 90 dba's |
| What is a HCP | Hearing Conservation Program |
| What are the 5 Classes of fires? | Class A- Ordinary Combustibles, Class B- Flammable liquids/gases, Class C- Electrical, Class D- Metal, Class K- cooking |
| What type of fire would you fight with water? | Class A- Ordinary Combustibles |
| What type of fire would you fight with CO2? | Class B & C - Flammable liquids/gases/Energized electrical |
| How far should you stand from a fire while using a Fire Extinguisher | 20-30 feet |
| Explain the PASS acronym | Pull the pin, Aim the extinguisher, Squeeze the trigger, Sweep side to side |
| When digging a trench, how far from the trench should excess dirt be placed | 2 feet |
| When placing a ladder in a trench, how far must the ladder extend? | 3 feet |
| When digging a trench, how far down until a ladder is required for entrance/exit? | 4 feet |
| When digging a trench, how far down until shoring is required? | 5 feet |
| When digging a trench, how far down until FPAS is required for all who pass across it? | 6 feet |
| When digging a trench, how far down until specially enginereed shoring is required? | 20 feet |
| When digging a trench, how far down until a ladder can no longer be used to enter/exit? | 25 feet |
| Plywood used for shoring must be at least _______ | 1 1/8" thick |
| Wood uprights used for shoring must be at least _________ | 2" x 8" |
| Do not slope a shored trench more than _______ | 15 degrees |
| A non-shored trench 20 feet or less must be sloped ______ | 1 1/2 feet back for every 1 foot down |
| Certification is required by Cal/OSHA for operating a crane with a capacity of over ________ | 3 tons |
| Safety toe shoes should protect against ______ volts | 600 volts |
| Shoring must be __________ after 20 feet | enginereed |
| OSHA defines an "asbestos infested roof" if the roof contains _______ % or more asbestos | 1 |
| Scaffolding that is erected ________ feet or higher, must have additional fall protection | 10 |
| residential construction uses __________ traffic cones during day and _________ traffic cones during the night | 18", 28" |
| How often should scaffolding be secured to a building? | every 30' horizontally and 26' vertically |
| scaffolds should be erected at least ______ feet away from a power line | 10 |
| cranes should operate at least _______ feet away from a power line | 20 |
Created by: