7&8 product&emission Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| What generates most of the heat created in the anodes? | The constant excitation and return of outer shell e-. |
| Ejection of an inner shell electron is __________ radiation | characteristic |
| In characteristic radiation, the x-ray has energy equal to the .... | difference in the binding energies of the orbital e- involved. |
| Tungsten K shell # of e- and binding energy? L shell? | 2 e-, 69keV. 8 e-, 12 keV |
| __________ has very specific energies. __________ x-rays produced can have any energy up to 70keV. | characteristic, brems |
| In the dx range, most x-rays are __________. (charact or brems) | brems |
| at 65 kVp, no useful _______ x-rays are produced; therefore, the beam is all _________. | characteristic, brems |
| At 100 kVp, approx 15% of the beam is ___________, the rest is _______. | characteristic, brems. |
| A ______ spectrum contains only specific values. | discrete |
| A _________ spectrum contains all possible values. | continuous |
| The discrete energies of characteristic x-rays are characteristic of the differences between | electron binding energies in a particular element |
| Characteristic x-rays have fixed energies, and form a ____ emission spectrum. | discrete |
| Bremsstrahlung have a range of energies and form a _________ spectrum | continuous |
| Brems emission spectrum extends from 0- max projectile electron energy, with the highest number of x-rays having approx. _______________ | 1/3 the max energy |
| Factor: tube current. Effect: | amplitude of spectrum (up and down) ..........current is mA/mAs |
| Factor: Voltage. Effect: | Amplitude and position (up and down, left/right) |
| Factor: Added Filtration. Effect: (and when) | Amplitude (up/down), most effective at low energy |
| Factor: Target material. Effect: | Amplitude (up/down), position (left/right) |
| Factor: Voltage waveform. Effect: (and when) | Amplitude (up/down) most effective at high energy |
| The farther to the right a spectrum is..... | the higher the effective energy or quality of beam. |
| The larger the area under the curve.... | The higher the x-ray intensity or quantity. |
| A change in mA or mAs results in a proportional change in amplitude at ____________ across the spectrum. | all energies |
| Change in kVp results in an increase in the amplitude at all energies but a greater increase at ______ energies than _____. Therefore, the spectrum shifts to the _____/_____ side. | high, low. Right/high energy |
| The maximum energy of x-ray emission always remains numerically equal to the | kVp |
| A change in kVp has what effect on the position of the discrete spectrum? | none |
| Discrete emission spectrum shifts to the _____ with an increase in the atomic # of target material. What happens with the continuous spectrum? | right. Slight increase in amplitude. (more effect on characteristic/discrete) |
| Increasing target atomic # enhances the efficiency of x-ray production and the energy of what x-rays? | characteristic and brems |
| Difference between three-phase/6-pulse and three-phase/12-pulse power? | simply the reduced ripple obtained with 12 pulse generators. |
| ______ generators are based on fundamentally different electrical engineering. | High frequency generators |
| Because of reduced ripple, operation with 3-phase or high frequency is equivalent to an approx ______% increase in kVp, or almost doubling of mAs over single phase power. | 12% (..or 16%?) |
| What is "grays in air" measurement? | quantity, exposure, intensity |
| What does the standard x-ray machine produce? | 50 uGy/mAs at 70 kVp measured at 100 cm SID |
| intensity of the beam is measured in | milligray in air (mGya) (formerly milliroentgen (mR)) called x-ray quantity |
| mGya (mR) is a measure of the # of ____ ____ produced in air by a quantity of x-rays | ion pairs |
| x-ray quantity is proportional to the | kVp ^2 |
| inherent filtration for a machine is approx | .5 mm Al equivalent (total with added must be 2.5) |
| Added filtration for a machine is approx.? | 2 mm Al equivalent. (total with inherent must be 2.5) |
Created by:
Zoest35
Popular Radiology sets