Physics Review 4-6 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| Evaluating radiographic quality requires the radiographer to assess the image for both: | * visibility of recorded detail (photographic properties) * sharpness of recorded detail (geometric properties) |
| photographic properties of recorded detail that are determined by the extent to which the structural components of the anatomic area of interest can be seen on the recorded image | visibility of recorded detail |
| Visibility of the recorded detail is achieved by the proper balance of ________ and _________. | radiographic density and radiographic contrast |
| the amount of overall blackness produced on the image after processing | radiographic density |
| Factors that directly affect density are identified as: | controlling factors |
| Factors that indirectly affect density are identified as: | influencing factors |
| Controlling factors for density: | * mA * exposure time |
| mA and exposure time are ________ proportional to quantity of x-rays produced | directly |
| mA & exposure time have an _________ relationship when maintaining the same mAs | inverse (reciprocity law) |
| A change in mAs results in a ________ change in radiographic density. | direct |
| What is the primary responsibility of a radiographer? | to evaluate radiographic images to determine whether sufficient information exists for a diagnosis |
| Radiographic quality is the combination of ________ and ________. | visibility and sharpness of recorded detail |
| determined by the extent to which the structural components of the anatomic area of interest can be seen on the recorded image | photographic properties |
| Factors that affect the visibility of the recorded detail is achieved by the proper balance of ________ and ________. | density and contrast |
| photographic quality when visibility of recorded detail is maximized | optimal |
| photographic quality when visibility of recorded detail is adequate or acceptable | diagnostic |
| photographic quality when recorded detail is not adequately visualized & the image must be repeated | unacceptable |
| Visibility of recorded detail is achieved by the proper balance of ________ and ________. | density and contrast |
| the amount of overall blackness produced on the image after processing | radiographic density |
| A radiograph that is too light has ________ density. | insufficient |
| A radiograph that is too dark has ________ density, and the anatomic part cannot be well visualized. | excessive |
| True or False: Knowledge about the factors that affect the density on a radiograph is critical to developing effective problem-solving skills of a radiographer. | True |
| Factors that directly affect something are called ________ factors. | controlling |
| Factors that indirectly affect something are called ________ factors. | influencing |
| has a primary effect on the amount of density | quantity of radiation reaching the IR |
| What happens to density when you increase the mAs? | the density increases |
| What happens to density when you decrease the mAs? | the density decreases |
| mAs can be doubled by: | doubling the mA or doubling the exposure time |
| Shape distortions appear in 2 different ways: | 1. Foreshortening 2. Elongation |
| How should you adjust the technical factors to prevent blooming? | Increase kVp and Decrease mAs |
| To adapt an adult technique to a pedi technique for a 6 to 12 yr old: | Decrease mAs by 50% |
| How much should you adjust the mAs to make any density change? | by 30% |
| increasing kVp by 15% will have the same effect on radiographic density as doubling the mAs; a 15% decrease will have the same effect as halving the mAs...what rule is this? | The 15% Rule |
| A radiograph of the pelvis is produced using 25 mAs at 70 kVp. What kVp would be needed to double the exposure? | 81 kVp (15% of 70 kVp + 70 kVp = 80.5 or 80 kVp) |
| Given an original technique of 30mAs & 80kVp, provide 2 possible ways of doubling the density. | 1. Double your mAs or: 2. increase the kVp by 15% (80kVp x 1.15 = 92 kVp) |
| the relationship between distance & x-ray beam intensity is best described by | The Inverse Square Law |
| States that the intensity of the x-ray beam is inversely proportional to the square of the distance from the source | The Inverse Square Law |
| What are the standard distances for most radiographic procedures? | 40', 48" or 72" |
| a device placed between the patient & the IR to absorb scatter radiation exiting the patient | Grid |
| Film screen systems are classified by relative speed (RS) factor. What is the relative speed (RS) range for film screen systems? | 50 to 800 RS |
| What relative speed (RS) film screen would you use to radiograph an extremity? | 100 RS |
| What is a routine high-speed film screen? | 400 RS |
| What 3 things make the effect of collimation on the radiographic density more visible? | 1. when imaging large anatomic areas 2. performing exams without a grid 3. using a high kVp |
| What type of relationship does film screen speed have with density? | direct relationship |
| What type of relationship does collimation have with density? | inverse relationship |
| What does a thick anatomic part do to radiographic density? | decreases it |
| What does a thin anatomic part do to radiographic density? | increases it |
| How much should the radiographer adjust the mAs for every change in part thickness of 4cm? | by a factor of 2 |
| The visibility of the anode heel effect on a radiographic image depends on 3 things...what are they? | 1. the SID used 2. the x-ray beam field size 3. the anatomic area of interest |
| The anode heel affect is more visible when... | you have a short SID & a large x-ray field size |
| states that the density produced on the radiograph will be equal for any combination of mA and exposure time, as long as the product of mAs is equal. | Reciprocity Law |
| When can reciprocity failure occur? | if using intensifying screens & extreme exposure times ( >10s or <10ms) |
| Do 3-phase units require higher or lower technique settings to produce a comparable image compared to a single phase unit? | Lower technique settings |
| When using compensating filters, should the mAs be increased or decreased in order to maintain the overall radiographic density? | increased |
| Processing of the film after exposure to radiation has a major effect on: | density & contrast |
| What conditions during film processing can adversely affect the radiographic density or contrast? | processor temperature, chemistry, or film transport |
| True or False: Exposure factor's effects on the intensity of radiation holds true for digital imaging. | True |
| True or False: The relationship between mAs and density is not the same for digital imaging as it is for film-screen imaging. | True |
| What percentage of exposure errors can adequately be adjusted during digital image processing? | 50% |
| What describes the concept of density as it is displayed on a soft-copy monitor for digital images? | brightness |
| the degree of difference between adjacent densities | contrast |
| an image that has sufficient density but no differences in densities | a homogeneous object |
| radiographic contrast is the combined result of 2 categories: | film contrast & subject contrast |
| refers to the contrast that is a result of the inherent properties manufactured into the type of film and how it is radiographed, along w/the processing conditions | film contrast |
| contrast that is a result of the absorption characteristics of the anatomic tissue radiographed and the level of kVp used | subject contrast |
| a radiograph with few densities but great differences among them | High contrast (short-scale) |
| a radiograph with a large number of densities but little differences among them | Low contrast (long-scale) |
| controlling factor for contrast | kVp |
| influencing factors affecting contrast: | grids, collimation, OID, anatomic part, contrast media, processing |
| unwanted density on a radiograph | fog |
Created by:
kkant
Popular Radiology sets