Carlton Adler Ch 41 Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
| Question | Answer |
| what is a tomogram? | the actual image? |
| what is a tomograph? | the piece of equipment used |
| what is tomography? | the modality/ exam |
| principle of tomography | synchonized movement of two elements, objects in plane of fulcrum sharp, objects farther away blurred |
| pivot point around the movement occurs, object being examined is placed at this point | fulcrum |
| where is object being imaged placed? | fulcrum |
| method to overcome superimposition | tomography |
| three elements of tomography | tube, object, IR |
| terms used to describe section of interested in tomography | slice or cuts |
| what is the result of a tomographic image? | area of fulcrum is sharp because it has not moved in relationship to tube & IR during position |
| arc or angle the tube travels. Total distance traveled by the tube | tomographic amplitude |
| arc or angle the tube travels during the exposure | exposure amplitude |
| what kind of slices do we take in tomography | only coronal slices |
| blurring of anatomic structures lying outside to focal plane | motion blur |
| what is properly imaged in tomography | only the object lying in the focal plane |
| how is blur demonstrated on the tomogram? | objects lying outside focal plane demonstrate increasing blur the further away from the object plane |
| how does blur effect density? | increased blurring causes decreased density. Objects are more transparent, permits objects with the focal plane to be seen through the blurring |
| how is tomographic amplitude (arc) related to blur | direct relationship. Increase in arc, increase in blur |
| how is distance from fulcrum related to blur? | directly. Increase in distance of an object from fulcrum, increase in blur |
| how is distance from IR related to blur? | directly, increase in object from IR, increase in blur |
| as the tube approaches perpendicularity, what happens to blur? | blur increases |
| blurred edges or margins | phantoms |
| when are phantoms produced? | during complex tomographic motion |
| occurs when tube motion is parallel to long axis of object | phantoms |
| The tomographic arc is greater or less than the exposure arc? | greater than or equal to |
| the exposure arc is greater or less than the tomographic arc? | less than or equal to |
| what decreases phantom images | reduced section thickness and increased exposure amplitude |
| pivot point | fulcrum |
| how do you adjust fulcrum? | move table up or down OR move fulcrum up or down, patient remains stationary. |
| region within the image exhibits satisfactory recorded detail and is controlled by the fulcrum | focal plane |
| controlled by the exposure angle (amplitude) | width of the focal plane |
| what is the relationship between thickness and exposure angle? | inverse relationship- as angle increases, section thickness decreases. |
| what determines section thickness? | tomography angle |
| controlled at the table, increments of 1/2 cm or 1 cm. | section interval |
| cannot exceed the section thickness | section interval |
| most common and most widely used type of motion | linear |
| variety of motions | pluridirectional |
| types of pluridirectional movements | curvilinear, circular, elliptical, figure eight, trispiral, hypocycloidal |
| slice thickness relationship to movements | more complex motion uses thinner slices |
| must match length of time required for x-ray tube to complete the tomo amplitude | exposure time |
| what kind of mA used for tomogram? | low mA, 100 mA |
| narrow angle, small exposure amplitude, 10ยบ arc- produce thick sections, application in chest and renal studies | Zonography |
| when lesion has been localized and fine detail is needed - produces thinner sections | wide angle tomography |
| curved, used mostly for head, mandible. Tube & IR collimated to a slit and travel in opposite directions | panoramic tomography |
| technique used to produce rad image with depth perception, making it 3D | stereoradiography |
| common uses for stereoradiography | chest, skull, shoulder, sinus, FB |