ARRT registry review covering image production
Quiz yourself by thinking what should be in
each of the black spaces below before clicking
on it to display the answer.
Help!
|
|
||||
---|---|---|---|---|---|
show | mA x seconds
milliroentgens/ mAs
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | 200x.015=3
80/3=27
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | true
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (465). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | more
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
Does more kVp give you more or less exposure | show 🗑
|
||||
Where is the image intensifier located for flouro | show 🗑
|
||||
Where is the xray tube for flouro | show 🗑
|
||||
what is the xray table made from | show 🗑
|
||||
what do electrostatic lenses do | show 🗑
|
||||
show | greatest source of acute radiation exposure in diagnostic- most dose
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
input phosphor sizes and material | show 🗑
|
||||
output phosphor size and material | show 🗑
|
||||
how can you decrease magnification without mag mode button | show 🗑
|
||||
off center | show 🗑
|
||||
show | not straight behind the patient, decrease of exposure entire image
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
off focus | show 🗑
|
||||
show | no exposure on outside of the image
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
AEC is usually | show 🗑
|
||||
show | AEC, is the safety mechanism to shut off exposure
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
Problems with AEC | show 🗑
|
||||
which interactions are radiation production | show 🗑
|
||||
Bremmstahlung | show 🗑
|
||||
show | max kVp chosen is the most energy a brem can produce
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
Brem | show 🗑
|
||||
Brem | show 🗑
|
||||
show | less than 1% turns to xray and the other turns to heat
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | the more change in direction is the more loss of energy
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
xrays are produced where | show 🗑
|
||||
electrons come from | show 🗑
|
||||
show | incoming ELECTRONS slows around nucleus in the target atom
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
Characteristic | show 🗑
|
||||
show | e comes in with same energy as inner shell electron knocks it out
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | then xray is produced
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | the next shell replaces the one that was booted out
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | Discrete graph, want k shell to be ejected
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
transformer laws | show 🗑
|
||||
show | ts/tp
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | ts/tp= vs/vp
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | ts/tp=Ip/Is
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
turns ratio | show 🗑
|
||||
show | more than = step up
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
three phase 6 pulse | show 🗑
|
||||
show | voltage ripple 3-4
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet(Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | 60 cycles of sinusoidal wavelength per 1 sec in US
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
pulses | show 🗑
|
||||
show | used for safety
cold anode=cracking
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet(Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
heat units | show 🗑
|
||||
reciprocal resistance | show 🗑
|
||||
show | f increases, wavelength decreases
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet(Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | f increases, energy increases
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
energy and wavelength | show 🗑
|
||||
show | kvp, penetration power
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
quantity | show 🗑
|
||||
primary | show 🗑
|
||||
show | exits patient toward receptor
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | electromagnetic radiation
heterogenous (not all same energy level)
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | travel at speed of light
high frequency and short wavelength
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
show | the central ray is not centered to the center of the grid
Schmuck, H. (2020). RADT465 Unit 2: Image Production/Equipment Operation and Quality Assurance Worksheet (Unpublished course reference). University of Southern Indiana, Evansville, IN.
🗑
|
||||
fundamental properties | show 🗑
|
Review the information in the table. When you are ready to quiz yourself you can hide individual columns or the entire table. Then you can click on the empty cells to reveal the answer. Try to recall what will be displayed before clicking the empty cell.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
To hide a column, click on the column name.
To hide the entire table, click on the "Hide All" button.
You may also shuffle the rows of the table by clicking on the "Shuffle" button.
Or sort by any of the columns using the down arrow next to any column heading.
If you know all the data on any row, you can temporarily remove it by tapping the trash can to the right of the row.
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Created by:
pacourtrig
Popular Radiology sets