Ultrasound Word Scramble
|
Embed Code - If you would like this activity on your web page, copy the script below and paste it into your web page.
Normal Size Small Size show me how
Normal Size Small Size show me how
Question | Answer |
First Italian Physicist to document use of waves by analyzing navigation of flying bats in the dark | Lazaro Spallanzani |
What year Lazaro Spallanzi document the waves from flying bats | 1794 |
He created an apparatus that produces sound waves of frequency of 40 Hz | Francis Galton |
What year Francis Galton created an apparatus | 1880 |
They noted that electricity maybe created by Piezoelectric Effect | Jacques and Pierre Curie |
They discovered the inverse piezoelectric effect | Jacques and Pierre Curie |
He discovered motion of the internal parts of bodies by the sound they make | Robert Hooke |
He registered a patent for iceberg detection and in what year | Lewis Fry Richard Soon, 1913 |
They invented Sonar (sound navigation and ranging or sonic navigation and ranging) and in what year | Paul Langevin and Constantin Chilowski, 1915 |
He developed sonar | Robert Boyle |
Type of ultrasound that is use for treatment | Therapeutic US |
He created a system in which the receiver was a separate device collecting the waves in 1941 | Donald Sproule- |
He received a recognition for the Reflectoscope | Floyd Firestone- |
He introduced hyperphonography | Karl and Friederick Dussik- |
Noted for developing the 1st application of ultrasound to the human body | George Ludwick |
He detected heart motions with a flaw detector and later called ECHOCARDIOGRAPHY in 1953 | Professor C. H. Hertz |
The first real-time mechanical commercial scanner in 1965 | VIDOSON |
Who designed VIDOSON | Richard Soldner |
A phased array system in 1983 | HEWLETT PACKARD 70020A |
He incorporated US into OB/GYN in 1958 | Ian MacDonald |
They designed pulsed doppler US Tech in 1966 | Don Baker, Dennis Watkins, and John Reid |
Color Doppler Sound Intruments in what year | 1970 |
He developed 3-D US captured images of fetus in 1980 | Kazunori Baba |
A test that uses US waves to capture images in the Body | US |
Travels in straight line through air or medium that can be heard | Sound |
Bumping of particles creates what | Sound waves |
It is a local oscillation in a medium that transfers energy through medium | Mechanical Wave |
Height of the wave's crest which determines its loudness | Amplitude |
A region in a sound wave where particles have been pushed together making the densest part of the wave | Compression |
The number of waves produced in a given period of time | Frequency |
The intensity of the pressure wave resulting in the level of intensity perceived by someone | Loudness |
Describes the perceived highness or lowness of a sound wave | Pitch |
The region in the sound wave where the particles have been spread out and are the least dense part of the wave | Rarefaction |
The measurement of a sound wave from compression to compression | Wavelength |
Frequency of an US wave | > 20 000 Hz (20 KHz) |
Active elements found in US Transducers | Piezoelectrics |
The ability of certain materials to generate an electric charge in response to applied mechanical stress | Piezoelectric Effect |
Piezein and piezo means what | Piezein = Squeez or Press Piezo = Push |
Less resolution but deeper penetration | Lower Frequencies |
Short wavelength but greater resolution | Higher Frequencies |
mHz for kidney and liver | 1-6 mHz |
mHz for muscles and tendons | 7-18 mHz |
Amplification is done by what | TGC - Time Gain Compensation Amplifier |
The decreasing of intensity of a sound wave | Attenuation |
The results of sound wave interaction with tissues | Divergence Interference Scatter Diffraction Absorption Reflection |
Echoes are large, smooth surface and sound is reflected in a singular direction (Bones) | Specular Reflector |
Small echoes, irregular shape and reflection returns in various directions (Soft Tissues) | Diffuse Reflector |
Refers to the propagation of incident sound waves in oblique directions | Scatter |
Occurs at interfaces involving structures of small dimensions | Rayleigh Scattering |
When the sound wave is greater than the structure it comes in contact with, it creates a uniform amplitude in all directions with little or no reflection returning to the transducer | True |
Most of the acoustic energy is reflected - impossible to see deeper | Gas or Solids |
Why lungs can't be examined by US | because of the presence of Air |
Imaging through an adult skull or other bones is possible | False, not. |
Attenuation is a combined effects of... | Absorption, Scattering, and Reflection |
The higher the angle of incidence, the lesser sound scattering | True |
Bending of waves can cause artifacts like spatial distortion and lesser resolution | True |
Absorption of US wave in fluids is a result of frictional forces that oppose the motion of particles in medium | True |
Physical property of tissues and describes how much resistance US beam encounters | Acoustic Impedance |
Density and speed is directly proportional to acoustic impedance | True |
Impedance is defined as | Z = pv |
Z P V stands for | Z = Acoustic Impedance P = Density of medium V = Speed of sound |
Found in the body where sound wave travels the fastest | Bone - 4080 m/s |
Found in the body where sound wave travels the slowest | Air - 330 m/s |
Ratio of intensity of reflected wave relative to incident wave | Intensity Reflection Coefficient |
The greater the difference in acoustic impedance between the media the greater the reflection and smaller the transmission | TRUE |
Reflection Fraction Formula | RF = [ ( Z2 - Z1 ) / ( Z2 + Z1 ) ] ^2 |
A method of describing the reflecting echoes | Echogenicity |
Darker and less reflection | Hypoechoic - Muscles, Blood Vessels |
Brighter and more reflection | Hyperechoic - Bones, Cartilage |
Total Black and no echoes | Anechoic - Air, Fluids |
Equal | Isoechoic |
Basic Components of a US | Pulser - Trasnducer - Receiver |
It applies high amplitude voltage to energize crystals | Pulser |
Converts electrical energy to mechanical energy | Transducer |
Detects and amplifies signals | Receiver |
A type of transducer that is propagated in linear fashion and is parallel to transducer surface | Linear |
It increases field of view and is ideal for deeper structures | Curvilinear |
Ultrasound Machine consists of what | Transducer Probe, a central processing unit (CPU), a monitor, a keyboard with control knobs, disk storage devices, a printer and so on |
A fluid medium needed to provide a link between transducer surface of the patient | Acoustic Coupling Agent |
Not a good coupling agent because it evaporates rapidly | Water |
Not a good coupling agent because it dissolves the rubber | Oil |
Best Acoustic Coupling Agent | Water Soluble Gel |
Most Essential Component in US | Transducer Probe |
Piezoelectric effect is also known as | Pressure electric effect |
The transducer head has a | Footprint |
Can be a notch, a dot or a light on the probe’s head and use for orientation | Probe Marker |
Probe that is not good for curve structures but good near field resolution | Linear Probe |
Produces a fan like image and increase width in deeper penetration but poor near field resolution | Sector/Phased Array |
The frequency ranges 2 to 7 MHz and perfect for abdominal scanning | Curvilinear |
Has a small footprint with a Hz range of 5-12 MHz. Designed to fit in encocavitary spaces | Transvaginal/Endocavity |
Controls the strength of electrical voltage | Power/Output Control |
Allows to increase and decrease field of view | Depth |
Adjusts overall brightness | Gain |
Allows adjustment of brightness at a specific depth of image | TGC |
it is placed at the depth of interest | Focal Zones |
Allows image to be held frozen | Freeze |
Used for moving objects on monitor | Trackball |
Allows magnification | Zoom |
Mode of scanning or known as Brightness Mode and use to get back to grey scale imaging from color Doppler and/or Pulsed Wave Doppler | 2D Knob - B mode |
Displayed as Measure or Cal(Calculation) on the ultrasound console | Measurement |
Simplest form of US imaging Based on Echo Principle 1D information | A-mode or Amplifier Mode |
If watched in a rapid sequence, they become real time images | B-mode |
Appears in the lower half of the screen | Spectral Doppler or Pulsed Wave Doppler |
Can be moved by operator and placed within a vessel as imaged by color doppler | Spectral Doppler or Pulsed Wave Doppler |
Cursor line appears on the upper section of the image. Primarily to document motion | M mode or Motion mode |
BART | Blue Away Red Towards |
Uses a color map to display information based on frequency | Color Flow Doppler |
Uses a color map to show distribution of power or amplitude | Power Doppler |
What activates color flow | Color flow knob |
Ultrasound is continuous and measures high velocities | Continuous wave doppler unit |
Measure the speed of blood in a vessel | Pulsed Wave Doppler |
The change of frequency of refection by a moving surface | The Doppler Effect |
Created by:
user-1782281
Popular Sonography sets